Sign In | Join Free | My udpf.com |
|
Certification : ISO9001-2000
Model NO. : XRNT4
Poles Number : 1
Type : Fuse
Function : Overcurrent Protection
Usage : High Voltage
Fusing Speed : High
HS : 8535100000
Standard : Germany DIN
Fusing Device : Link Break
Shape : Circle
Transport Package : Foam Carton and Wooden Packing
Specification : 24Kv
Trademark : Wuhuan
Origin : Xi′ an China
HS Code : 8535100000
Supply Ability : 5000/Capacity per month
Breaking Capacity : High Voltage Circuit Breakers
Operation : Electric Type
Speed : High-Speed Circuit Breaker
Arc-extinguishing Medium : Oil-immersed Type
Installation : Insert
Structure : MCB
Samples : US$ 5/Piece 1 Piece(Min.Order) | Request Sample
Customization : Available | Customized Request
MOQ : 1
Price : RMB 168-2878/Piece 1 Piece (Min. Order)
Delivery Time : 10 weekdays
Payment Terms : L/C ,D/P , T/T ,Western Union ,MoneyGram ,Paypal
Place of Origin : China
Brand Name : xawh
High Voltage Current Limiting Fuse for Oil-Immersed Transformer Backup Fuse Protection
XRNT4-15.5, XRNT4-24, XRNT4-40.5 High voltage fuses for oil immersed transformer backup protection
The series high voltage current limiting fuses of XRNT4-15.5, XRNT4-24, XRNT4-40.5 for oil immersed transformer protection, they are suitable for rated AC power of 50Hz, rated voltage of 15.5kV, 24kV, 40.5kV power system.
As a power transformer and other power equipment short circuit fault protection element. The fuse is installed in the transformer oil of the American transformer , which can be used in the same box with load switch of transformer .
The high voltage current limiting fuse can be connected in series with the high voltage transformer overload protection fuse to form the high voltage current limiting fuse of full range protection. The high voltage fuse will break the circuit , when the overload current exceeds the specified value for a little time. The high voltage backup fuse will break the short circuit current , when the wrong current passes through the fuse .The product can be widely used in equipment distribution protection of wind power generation, solar power generation, tidal power generation and so on .
This product has the characteristics of not causing any pollution to transformer oil when breaking short circuit current, stable time-current characteristic curve, significant current limiting characteristics of backup fuse, strong breaking ability, the maximum breaking current can reach 50kA.
1. Model and meaning :
Fuse model number | Rating current of fuse | Dimmension(ΦC*A) | B | Type of wiring screw |
XRNT4-15.5 | 20, 25 , 31.5 , 40 , | Φ53*216 | 248 | M6 |
50 , 63 , 80 , 100 , 125 | Φ53*324 | 356 | M6 | |
150 , 175 | Φ53*373 | 405 | M6 | |
200 , 250 | Φ76*462 | 494 | M10 | |
315 | Φ76*567 | 600 | M10 | |
XRNT4-24 | 25A , 31.5A , 40A , 50A , 63A , 80A , 100A | Φ76*462 | 494 | M10 |
125A , 160A , 200A | Φ76*567 | 600 | M10 | |
XRNT4-40.5 | 10A , 16A , 20A , 25A | Φ76*462 | 494 | M10 |
31.5A , 40A, 50A , 63A | Φ76*567 | 600 | M10 | |
80A , 100A | Φ76*650 | 682 | M10 | |
125A | Φ76*750 | 782 | M10 |
2.Time-current characteristic curve of XRNT4 fuse as below :
With the broadest array of transformer components for ANSI/IEEE design type equipment, we supply transformer and switchgear OEM's with the reliable products needed to service their component requirements. Tap changer, series multiple, loadbreak and sectionalizing switches, as well as apparatus bushings are examples of the numerous products available from the industry's largest supplier of transformer components.
Components & Protective Equipment:
Fault Indicators
Fusing Equipment
Expulsion Links
Bay-O-Net
NX Current Limiting
X-limiter Current Limiting
NX Companion Back-up C
ELF Current-Limiting
Tandem ELF
L Bay-O-Net
ELSP Fuse
Encapsulated Fuse
Magnex Interrupter
Transformer Components
Secondary Bushings
Bushing Wells
Integral Loadbreak Bushing
600A Bushings
Arrester Disconnect
Tap Changer
Sectionalizing Switch
Two positions/Four positions/Three positions Loadbreak Switch
Series - Multiple Switch
![]() |
Link Break Fault Limiting Fuses 1 Poles For Oil Immersed Transformer Images |